Specifications
| ACOUSTICAL | |
| Compatible Models | ULTRA-X20 / ULTRA-X22 / ULTRA-X23 |
| Operating Frequency Range3 | 60 Hz – 18 kHz |
| Frequency Response4 | 65 Hz – 17.5 kHz ± 4 dB |
| Phase Response | 95 Hz – 18 kHz ±45° |
| Linear Peak SPL5 | [ULTRA-X20]: 127 dB with 20 dB crest factor (M-noise), 123.5 dB (Pink Noise), 125.5 dB (B-noise) [ULTRA-X22]: 128.5 dB with 20 dB crest factor (M-noise), 123.5 dB (Pink Noise), 125 dB (B-noise) [ULTRA-X23]: 127.5 dB with 20 dB crest factor (M-noise), 124 dB (Pink Noise), 125.5 dB (B-noise) |
| COVERAGE | |
| Horizontal x Vertical | [ULTRA-X20]: Rotatable horn: 110° x 50° [ULTRA-X22]: Rotatable horn: 80° x 50° [ULTRA-X23]: 110° x 110° |
| TRANSDUCERS | |
| Low Frequency | Two 5-inch cone drivers; 6 Ω nominal impedance |
| High Frequency | One 2-inch diaphragm compression driver connected to a rotatable horn; 8 Ω nominal impedance |
| AUDIO INPUT (ANALOG / DIGITAL VERSION) | |
| Input Type | [Analog]: Differential, electronically balanced | [Digital]: Milan Certified |
| Connectors | Analog Version: XLR 3-pin female input with male loop output (Optional XLR 5-pin for balanced audio + RMS); XLR 3-pin TOP (Total Outdoor Protection) for weather-protected units. Digital Version: etherCON TOP |
| Input Impedance & Common Mode | • Impedance: 10 kΩ differential between pins 2 and 3 • Max Common Mode Range: ±15 V DC, clamped to earth |
| Wiring (Analog 5-Pin)6 | Pin 1: Chassis/earth (via 1 kΩ, 1000 pF, 15 V clamp) Pin 2: Signal + / Pin 3: Signal – Pin 4: RMS / Pin 5: RMS (polarity insensitive) Case: Earth ground and chassis |
| Sensitivity & Input Level | • Nominal Sensitivity: 0 dBV (1.0 V rms) continuous (onset of limiting) • Max Input Level: +20 dBV (10 V rms) into 600 Ω |
| AMPLIFIER | |
| Type & Cooling | Three-channel, Class-D / Convection cooling |
| Total Output Power7 | 860 W peak |
| THD / IM / TIM | <0.02% |
| AC POWER | |
| AC Power Connector | powerCON 20 input with loop output; powerCON TRUE1 TOP with loop output on digital and weather-protected units |
| Voltage Selection | • Automatic Voltage Selection: 90–265 V AC, 50–60 Hz • Safety Rated Range: 100–240 V AC, 50–60 Hz |
| Turn-on / Off Points | 90 V AC turn-on, no turn-off; internal fuse protection above 265 V AC |
| CURRENT DRAW | |
| Idle Current | 0.15 A rms (115 V AC); 0.13 A rms (230 V AC); 0.16 A rms (100 V AC) |
| Long-Term Continuous8 | 0.9 A rms (115 V AC); 0.5 A rms (230 V AC); 1.1 A rms (100 V AC) (>10 sec) |
| Burst & Peak Current | • Burst Current (<1 sec): 1.6 A rms (115 V) / 0.8 A rms (230 V) / 1.8 A rms (100 V) • Max Instantaneous Peak: 3.5 A peak (115 V) / 1.8 A peak (230 V) / 4.1 A peak (100 V) |
| Inrush Current | < 20 A peak |
| REMOTE MONITORING | |
| Monitoring Options | Analog Version: Optional RMS module (reports parameters via RMServer hardware to host PC). Digital Version: Integrated monitoring via Compass Control Software. |
| PHYSICAL | |
| Dimensions & Weight | W: 7.44 in (189 mm) x H: 19.04 in (484 mm) x D: 8.66 in (220 mm) Weight: 27 lb (12.3 kg) |
| Enclosure & Grille | Aluminum with slightly textured black finish; Powder-coated, round-perforated steel grille |
| IP Rating | Weather-protected version rated IP54 |
| Rigging | Two integrated M8 threaded points on each end; optional accessories available; four M6 threaded holes with 5″ x 2.75″ (127 mm x 70 mm) pattern on the rear for third-party wall mounts. |